Made of first-quality, polypropylene-based, thermoplastic rubber (TPR)
Outstanding compression characteristics and toughness for peristaltic pump uses
Available in both FDA and industrial grades
Natural 80A material is listed by the National Sanitation Foundation (NSF-51)
(Other durometers with an NSF listing are available as a custom item)
Made to Good Manufacturing Practices (GMP)
Notes
SUPRENE offers excellent flex fatigue resistance and good tear resistance, making it an ideal choice for peristaltic pump applications. The FDA material is suitable for a variety of clean uses and is autoclavable to ensure cleanliness.
Black industrial SUPRENE offers good resistance to U.V., ozone, chemicals, and other fluids. It will also handle applications where oil may splash onto the tubing and is well suited for outdoor use.
Specifications
·
Physical Properties
Specifications
I.D.
3/8
in
O.D.
0.500
in
Wall
1/16
in
Grade
Natural FDA
Durometer
80A
Standard Coil Length
50
ft
Weight/100 ft.
3.61
lbs
Physical Properties
Hardness, Shore A @ 77ºF, ±5
80
Tensile Strength @ 77ºF
1600
psi
Elongation at Break
450
%
Tear Strength @ 73ºF
194
pli
Compression Set @ 73ºF after 168 hrs.
29
%
Compression Set @ 212ºF after 168 hrs.
41
%
Brittle Temperature
<-76
ºF
Min. Recommended Operating Temp.
-60
ºF
Max. Recommended Operating Temp.
275
ºF
Notes
Values listed are typical for the material used in manufacture, except where noted, and are meant only as a guide to aid in design. Field testing should be performed to find the actual values for your application.