Print Back
Chemfluor®FEP Fluoropolymer Smooth Inner Tube
EPDM Rubber Cover

Features and Benefits
  • Unexcelled chemical resistance
  • Full vacuum rated
  • Durable, kink resistant, with no external wire reinforcement to potentially fray
  • Easy-to-clean, non-stick smooth tube for assured sterility
  • Can be cleaned with steam, caustics, solvents or other cleaning agents
  • Resistant to chemicals, ozone and abrasion
Note:
Extended Life Service Tip:
Flexible Components suggests using full-length anti-kink armor casing or at least 16'' to 24" long anti-kink cuffs at each fitting end to help reduce the strain on the crimp collar and fittings in high toad installations. Prolonged service at elevated temperatures will reduce total service life.
Unit of Measure

Specifications

Inside Diameter

N/A 4.00 in101.6 mm

Outside Diameter

N/A 4-23/32 in119.4 mm
Max. Working Pressure1 N/A 150 psi1.03 MPa

Max. Assembly Length

N/A 30 ft
Min. Burst Pressure2 N/A 600 psi4.14 MPa

Min. Bend Radius

N/A 34.00 in863.60 mm
Vacuum Hg (@ 70ºF)3 N/A 29.9 in75.95 mm

Max. Overall Length w. Anti-Klink Casing

N/A Consult Factory

Weight

N/A 3.60 lbs/ft5.36 kg/m

Color

N/A Green

Applications

N/A

  • Rail car unloading
  • Chemical trailer loading / unloading
  • Pumping stations
  • Portable pumps
  • Isolation dampeners
  • CIP
  • Food and beverage
  • Flavors
  • Load cell applicators
  • Caustic cleaning

Common Media

N/A

  • HF acid
  • HCL
  • H2SO4
  • Paint

Details

N/A Colors:

  • Green or white standard (white cover designated WTLCT)
  • TLCT covers can be color-coded to identify specific process lines or trace departments
  • Special colors available with minimum order quantities.
Construction:
  • Inner Tube: Chemfluor® FEP
  • Cover: EPDM rubber
  • Reinforcement:
    -Multiple polyester plycord and EPDM rubber
    -Double helix, high tensile strength carbon steel wire
Fittings:
  • Over 40 styles of stocked PermaSeal® crimp-style fittings
  • A wide range of materials available
  • Standard: 316L stainless steel (wetted surfaces)
  • Flare-Thru fitting technology available
    -150# swivel style flanges
    -Female cam and groove (swivel style, 316 stainless steel body)
    -Sanitary clamp style not available for TLCT/WTLCT/SFTL Series

Engineering Specifications

N/A Temperature Rating

  • -40ºF to +350ºF
  • -40ºC to +177ºC

Industry Approvals & Compliances

N/A

  • FDA approved per 31CFR177.1550
  • US Pharmacopeia Class VI

Pressure Rating

N/A Burst Pressure rating at ambient 70ºF (21ºC). See applicable notes on vacuum/pressure ratings at temperatures other than ambient
Working Pressure is given @ 70ºF; Decrease working pressure 1% for every 2ºF above 212ºF
Vacuum Rating is given @ 70ºF; Decrease vacuum rating 1% for every 2ºF above 212ºF. For 1-1/4'' and larger sizes, vacuum rating decreases when installed less than 2X min. bend radius
Flare thru fitting are pressure rated only. Not rated for vacuum service
Extended Service Life Tip: Flexible Components suggests using full-length anti-kink armor casing or at least 16'' to 24" long anti-kink cuffs at each fitting end to help reduce the strain on the crimp collar and fittings in high toad installations. Prolonged service at elevated temperatures will reduce total service life.

  • 1 Working Pressure is given @ 70ºF; Decrease working pressure 1% for every 2ºF above 212ºF
  • 2 Burst Pressure rating at ambient 70ºF (21ºC). See applicable notes on vacuum/pressure ratings at temperatures other than ambient.
  • 3 Vacuum Rating is given @ 70ºF; Decrease vacuum rating 1% for every 2ºF above 212ºF. For 1-1/4'' and larger sizes, vacuum rating decreases when installed less than 2X min. bend radius.