- Made from FEP fluoropolymer tubing
- Corrugations allow a nearly zero bend radius - easily flexed
- Can be extended or compressed without affecting the tube's I.D.
- Made from FDA-sanctioned ingredients
- Made without plasticizers which can leach into critical streams
- Has all the chemical and electrical properties of straight-walled FEP tubing
- May be over braided with Kevlar® for higher pressures. (Over braiding with Kevlar will permit a minimum increase of six times the listed pressures. Kevlar over braiding is available for sizes up to 7/8" I.D.)
Vacuum Service: 29.9 in./Hg.
Bend Diameter: 1/2 of tubing I.D.
Extension/Compression Length Ratio: 2 to 1
Optimal flow is achieved and turbulence minimized by passing fluids through CORRTEF in the direction of the corrugation angles (as illustrated).
CORRTEF is heat sealable, and the cuffs (straight ends) are made to accept standard barbed fittings. The end may be flared or expanded to permit shrink-tight connections.
CORRTEF is manufactured in an industrial atmosphere and should be properly sterilized for dean-flow applications. For optimal cleaning of CORRTEF, the tube should be stretched to its maximum length and held vertically (direction of flow: down). Due to the annular corrugations, it may not be possible to remove all traces of particulate from CORRTEF, even under optimal cleaning conditions.
Unit of Measure
Specifications
Max. I.D. (Dim. A) |
N/A 5/8 in |
Dim.- B1 | N/A 1 in |
Dim. C |
N/A 0.025 in |
Dim. D (Ref.) |
N/A 15/16 in |
Working Pressure at 70ºF |
N/A 37 psi |
Burst Pressure at 70ºF |
N/A 148 psi |
Physical Properties
Hardness, Shore D |
N/A 50-55 |
Tensile Strength |
N/A 3500 psi |
Elongation at Break |
N/A 325 % |
Brittle Temperature2 | N/A <-275 ºF |
Min. Continuous Svc. Brittle Temp.3 | N/A -100 ºF |
Max. Operating Temp.4 | N/A 400 ºF |
Max. Cont. Svc. Temp., Zero Pressure5 | N/A 200 ºF |
Notes |
N/A Values listed are typical for the material used in manufacture, except where noted, and are meant only as a guide to aid in design. Field testing should be performed to find the actual values for your application. |
- 1 Workable I.D. length of the cuff (straight ends). All lengths supplied with 'B' dimension cuffs.
- 2 Temperatures are for standard extruded (non-coiled) tubing.
- 3 Temperatures are for standard extruded (non-coiled) tubing.
- 4 Temperatures are for standard extruded (non-coiled) tubing.
- 5 Temperatures are for standard extruded (non-coiled) tubing.