Construction
AQP elastomer tube, reinforcement consisting of a helical wire between two textile braids and blue AQP elastomer cover.
Application
Suction and transfer applications for petroleum and fire resistant hydraulic fluids, fuel, lubricating oils, gasoline, water and many other industrial fluids.
Operating Temperature Range
-40°F to +302°F (-40°C to +150°C)
Exceeds SAE 100R4
Construction
AQP Elastomer Tube, single wire braid reinforcement and blue AQP elastomer cover.
Application
Hydraulic fluids, petroleum and fire resistant types, fuel, lubricating oils, gasoline, water, and other industrial fluids.
Operating Temperature Range
-40°F to +300°F (-40°C to +150°C)
Exceeds SAE 100R1A, meets or exceeds DIN 20 022 Type 1st
Construction
AQP elastomer tube, double wire braid reinforcement and blue AQP elastomer cover.
Application
Petroleum and fire resistant hydraulic fluids, fuel, and lubricating systems.
Operating Temperature Range
-40°F to +302°F (-40°C to +150°C)
Meets or exceeds: SAE 100R2A, EN 853 2ST, ISO 1436-1 Type 2ST
Construction
AQP elastomer tube, brass plated steel wire reinforcement, braided refractory insulation and blue AQP elastomer cover.
Application
Diesel fuel, gasoline, hot lube oil and water.
Operating Temperature Range
-40°F to +302°F (-40°C to 150°C)
Use with biodiesel not to exceed +212°F (+100°C) with B2 to B20.
Fire resistant USCG/MMT, NMMA/BIA
Construction
AQP elastomer tube, polyester inner braid, single wire braid reinforcement and blue polyester cover.
Applications
Hydraulics handling petroleum base fluids and air, gasoline, fuel and lubricating oils, fire resistant hydraulic fluids and other industrial fluids. Biodiesel use up to B20 and max temperature of 212°F (100°C).
Operating Temperature Range
-55°F to +302°F (-49°C to +150°C)
Air not to exceed +250°F [+121°C]
Use with biodiesel not to exceed 212°F (100°C) with B2 to B20.
*Maximum negative pressure shown for -16 and larger are suitable for those which has suffered no external damage or kinking. If greater negative pressures are required for -16 and larger hoses, the use of in internal support coil is recommended.
**-32 and -40 does not meet SAE 100R5 pressure with reusable fittings. -32 size rated to 350 psi with crimp fittings.
FC300 Crimp Fittings
Construction
AQP elastomer tube, textile braid reinforcement, AQP elastomer cover.
Application
For gasoline, fuel and lubricating oils, air and water. Not recommended for hydraulic impulse applications and not approved for airbrake applications.
Operating Temperature Range
-40°F to +302°F (-40°C to 150°C)
Air not to exceed +250°F [+121°C] and water not to exceed +180°F [+82°C]
Construction
AQP elastomer tube, 4 spiral wire reinforcement, and a blue AQP elastomer cover.
Application
Hydraulic system service with petroleum, fire resistant, and water-base fluids, fuel and lubricating systems.
Operating Temperature Range
-40°F to +302°F (-40°C to +150°C)
FMVSS106
Construction
AQP elastomer tube, polyester inner braid and a single wire braid reinforcement; black polyester textile braided cover.
Applications
Air, gasoline, fuel lubricating oils and coolants. Biodiesel use up to B20 and max temperature of 212°F (100°C).
Operating Temperature Range
-55°F to +302°F (-49°C to +150°C)
Air not to exceed +250°F [+121°C]
FMVSS106
Construction
AQP elastomer tube, polyester inner braid and a single wire braid reinforcement; blue AQP elastomer cover.
Applications
Air, gasoline, fuel lubricating oils and coolants. Biodiesel use up to B20 and max temperature of 212°F (100°C).
Operating Temperature Range
-40°F to +302°F (-40°C to +150°C)
Air not to exceed 250 psi or +250°F [+121°C]
FC355 Crimp Fittings
Construction
AQP elastomer tube, textile braid reinforcement, blue AQP elastomer cover.
Application
Low pressure return lines in hydraulic systems.
Operating Temperature Range
-40°F to +302°F (-40°C to 150°C)
Exceeds SAE 100R6
Construction
AQP elastomer tube, Hi-Pac braided wire reinforcement and blue AQP elastomer cover.
Application
Petroleum and fire-resistant hydraulic fluids, fuel, and lubricating systems.
Operating Temperature Range
-40°F to +302°F (-40°C to +150°C)
Construction
AQP elastomer tube, single wire braid reinforcement and blue AQP elastomer cover.
Application
Petroleum and fire-resistant hydraulic fluids, fuel and lubricating oils, gasoline, water and other industrial fluids.
Operating Temperature Range
-40°F to +300°F (-40°C to +150°C)
Meets or exceeds: SAE 100R1AT Type S, EN853 1SN, ISO 1436-1 Type 1SN
Construction
AQP elastomer tube, double wire braid reinforcement and blue AQP cover.
Application
Petroleum and fire resistant hydraulic fluids, fuel and lubricating systems.
Operating Temperature Range
-40°F to +302°F (-40°C to +150°C)
Meets or exceeds
SAE 100R2AT Type S, EN853 2SN ISO 1436-1 Type 2SN