Construction
Synthetic rubber tube, double wire braid reinforcement and DURA-TUFF™ synthetic rubber cover. Meets or exceeds EN requirements at ½ SAE Bend Radius.
Application
Hydraulic system service with petroleum and water-base fluids, for general industrial service.
Operating Temperature Range
-50°F to +260°F (-46°C to +127°C)
Meets or exceeds:
SAE 100R16 Type S, EN857 2SC, ISO 11237-1 Type 2SC
Construction
AQP elastomer tube, double wire braid reinforcement and blue AQP cover.
Application
Petroleum and fire resistant hydraulic fluids, fuel and lubricating systems.
Operating Temperature Range
-40°F to +302°F (-40°C to +150°C)
Meets or exceeds
SAE 100R2AT Type S, EN853 2SN ISO 1436-1 Type 2SN
Meets or exceed SAE 100R12, En 856 Type R12, ISO 18752, ISO 3862 Type R12, EN 856 SP Performance
Inner Tube
Synthetic rubber tube
Reinforcement
4-spiral wire reinforcement
Cover
DURA-TUFF™ synthetic rubber cover.
Typical Application
For very high pressure hydraulic lines subjected to pressure surges and flexing. Typical applications include construction, mining, farming, and high performance industrial equipment
Operating Temperature Range
-40°F to +260°F (-40°C to +127°C)
Fittings
4S/6S Series
Construction
Synthetic rubber tube, single wire braid reinforcement and DURA-TUFF™ synthetic rubber cover. Meets or exceeds EN requirements at ½ SAE Bend Radius.
Application
Hydraulic system service with petroleum and water-base fluids, for general industrial use.
Operating Temperature Range
-50°F to +260°F (-46°C to +127°C)
Meets or exceeds: SAE 100R1AT Type S, EN853 1SN, ISO 1436-1 Type 1SN
Construction
Synthetic rubber tube, double wire braid reinforcement and DURA-TUFF™ synthetic rubber cover.
Application
Hydraulic system service with petroleum and water-base fluids, for general industrial service.
Operating Temperature Range
-40°F to +260°F (-40°C to +127°C)
Meets or exceeds: SAE 100R2AT Type S, EN 853 2SN, ISO 1436-1 Type 2SN
Construction
AQP elastomer tube, single wire braid reinforcement and blue AQP elastomer cover.
Application
Petroleum and fire-resistant hydraulic fluids, fuel and lubricating oils, gasoline, water and other industrial fluids.
Operating Temperature Range
-40°F to +300°F (-40°C to +150°C)
Meets or exceeds: SAE 100R1AT Type S, EN853 1SN, ISO 1436-1 Type 1SN
Construction
Aeroquip brand exclusive low temperature compound tube and cover, double wire braid reinforcement. DURA-TUFF™ synthetic rubber cover.
Application
Low temperature flexing and hydraulic system service with petroleum and water-base fluids. For use in frigid environments on construction equipment and other mobile applications.
Operating Temperature Range
-70°F to +212°F (-57°C to +100°C)
Meets or exceeds: SAE 100R16 Types, EN 857 Type 2SC Performance
Exceeds SAE 100R16 Type S, EN 857 Type 2SC, ISO 11237-1 Type 2SC Performance
Inner Tube
Aeroquip brand exclusive low temperature compound tube and cover
Reinforcement
2 steel braids
Cover
DURA-TUFF™ synthetic rubber cover.
Application
Low temperature flexing and hydraulic system service with petroleum and water-base fluids. For use in frigid environments on construction equipment and other mobile applications.
Operating Temperature
-70°F to +212°F (-57°C to +100°C)
Fittings
TTC Series