Meets EN 857 Type 1SC
Inner Tube
Synthetic rubber tube
Reinforcement
1 steel braid
Cover
Synthetic rubber cover
Typical Application
Hydraulic system service with petroleum and waterbased fluids, for general industrial service
Operating Temperature
-40oC to +100oC (-40oF to +212oF)
Fittings
TTC Series
Two-piece Winner
Exceeds SAE 100R1 AT Type S, EN 857 1SC, ISO 1436-1 Type 1SC Performance
Inner Tube
Synthetic rubber tube
Reinforcement
1 steel braid
Cover
DURA-TUFFTM synthetic rubber
Typical Application
Low & medium pressure hydraulic systems, petroleum & water-based fluids, construction equipment, and agriculture equipment
Operating Temperature
-46oC to +127oC (-50oF to +260oF)
Fittings
TTC Series
Exceeds SAE 100R16 Type S, EN 857 Type 2SC, ISO 11237-1 Type 2SC Performance
Inner Tube
Aeroquip brand exclusive low temperature compound tube and cover
Reinforcement
2 steel braids
Cover
DURA-TUFF™ synthetic rubber cover.
Application
Low temperature flexing and hydraulic system service with petroleum and water-base fluids. For use in frigid environments on construction equipment and other mobile applications.
Operating Temperature
-70°F to +212°F (-57°C to +100°C)
Fittings
TTC Series
Meets or exceeds SAE 100R1AT Type S, EN 853 1SN, ISO 1436-1 Type 1SN performance
Inner Tube
AQP elastomer tube
Reinforcement
1 steel braid
Cover
Blue AQP elastomer cover
Typical Application
Petroleum and fire-resistant hydraulic fluids, fuel and lubricating oils, gasoline, water and other industrial fluids.
Operating Temperature
-40°F to +300°F (-40°C to +150°C)
Fittings
TTC Series
Exceeds SAE 100R17 Performance
Inner Tube
Synthetic Rubber tube
Reinforcement
4 to 8 size: 1 steel braid
10 to 16 size: 2 steel braids
Cover
Synthetic rubber intermediate cover and BRUISER outer cover
Typical Application
High abrasion industrial and hydraulic system applications with petroleum and water-based fluids. Recommended for use on critical applications in construction, forestry, and other off-highway vehicles. BRUISER outer cover offers unmatched abrasion, chemical, and environmental protection.
Operating Temperature
-40oC to +100oC (-40oF to +212oF)
Fittings
TTC Series